Maintenance Fluid Calculations

Determine maintenance IV fluid rates

Questions

1.Enter Weight

About

The maintenance fluid calculator was derived in 1957 by Holliday and Segar for the pediatric population but has persisted in use for both adults and pediatric patients to date. It was derived based on estimated energy expenditure amongst sicker children admitted to hospitals. The formula is based off of the assumption that hospitalized patients have greater energy expenditure and determines fluid requirements based on weight alone (a proxy for energy expenditure in a non-linear relationship).

Other maintenance fluid calculators have been derived and employed, however the "4-2-1" rule remains the most widely used for adults and pediatric populations secondary to its ease of calculation

Variable & Associated Points
Maintenance Fluid Rate is calculated based on weight.

  • 4 mL / kg / hour for the first 10kg of body mass
  • 2 mL / kg / hour for the second 10kg of body mass (11kg - 20kg)
  • 1 mL / kg / hour for any kilogram of body mass above 20kg (> 20kg)

References

Holliday MA and Segar WE.

The maintenance need for water in parenteral fluid therapy.

Pediatrics 1957, 19 (5): 823-32

The Maintenance Fluid Calculations calculator is created by QxMD.

Created by on 24/05/2019

By using this site you acknowledge that you have read, understand, and agree to be bound by our terms of use and privacy policy. All content and tools are for educational use only, are not meant to be a substitute for professional advice and should not be used for medical diagnosis and/or medical treatment.